SBX-1K SERIES SHEAR BEAM LOAD CELLS, from 500kg to 2000kg

Stainless steel approved shear beam load cells, suitable for creating CE-M approved scales with 4 load cells, or for weighing tanks and hoppers, with the aid of its accessories.

CAPACITIES (kg): 500, 1000, 2000.

OIML R60. C3 precision class.

Stainless steel. IP68 protection.

TECHNICAL FEATURES

  • Minimum load cell verification interval Vmin = EMax / 10.000
  • Maximum number of verification intervals nLC = 3000
  • Combined error 0,017% of Full Scale Output (F.S.)
  • Full Scale Output 2mV/V +/- 0.5%
  • Temperature effect on zero 0,002% / °C
  • Temperature effect on full scale output 0,002% / °C
  • Compensated Temperature Range -10°C/+50°C
  • Operating Temperature Range -20°C/+60°C
  • Creep error after 30 minutes 0,02% F.S.
  • Maximum tolerated excitation voltage 15 VDC
  • Input Resistance 1100 ± 20 Ohm
  • Output Resistance 1000 ± 20 Ohm
  • Insulation Resistance >5000 MOhm
  • Safe Overload 150% F.S.
  • Ultimate Overload 300% F.S.
  • 6-wire shielded cable, 5m long, 5 mm diameter
  • ATEX VERSION
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
  • ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
  • ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
  • The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

MAIN FEATURES

  • C3 PRECISION CLASS
  • STAINLESS STEEL CONSTRUCTION WITH LASER WELDING
  • IP68 PROTECTION
  • MAX. CAPACITIES FROM 500 TO 2000 kg
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

ATEX VERSION

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) GaATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.